Term
| List the 3 types of Sprinkler Control Systems |
|
Definition
| Post Indicator Valve (PIV), Outside Screw and Yoke (OS&Y), Wall indicator Valve (WIV) |
|
|
Term
| List Specs of a Class I Standpipe System |
|
Definition
| Designed for FD and trainned Personnel, 2 1/2" outlets, Minimum 500 GPM plus additional 250 GPM per riser, No hose provided at the hook ups, Hookd ups are near stairs or exits |
|
|
Term
| List Specs of a Class I Standpipe System |
|
Definition
| Designed for FD and trainned Personnel, 2 1/2 outlets, Minimum 500 GPM plus additional 250 GPM per riser, No hose provided at the hook ups, Hookd ups are near stairs or exits |
|
|
Term
| Specs of a class II Standpipe System |
|
Definition
| Designed for both trained and untrainded building occupants, has 1 1/2" outlets, minimum flow 100GPM, Hose is provided is single jacket unlined with a nozzle with no shut off, hose is not tested |
|
|
Term
| List Specs of a Class III Standpipe System |
|
Definition
| Designed fo both trained adn untrained personnel, has 500GPM Both 1 1/2" and 2 1/2" of a 2 1/2" with 1/2" reducer |
|
|
Term
| List the types of Building Constructions |
|
Definition
| Type I Fire Resistive, Type II Noncombustible, Typr III Ordinary, Type IV Heavy Timber, Type V Wood Frame |
|
|
Term
|
Definition
| Weight of all material attached to building |
|
|
Term
|
Definition
| Weight of people and equipment not attached |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|
Term
|
Definition
| Crowds of people, fire stream, gust of winds |
|
|
Term
|
Definition
| Number of BTU generated when a building and contents burns |
|
|
Term
| List signs of building collapse |
|
Definition
| Overall condition anf age of building,deterioration of mortor joints and masonary, cracks in anything sign of building repair including cables and tie rods, Large oen spans, bulging and bowing wals, sagging floors, abandoned buildings, large volume of fire,long firefightng operstions, smoke coming from cracks in walls, multiple fires in the same building |
|
|
Term
| Lis the NFPA standard covers use and care of ground ladders? |
|
Definition
|
|
Term
| List examples of ladder use |
|
Definition
| Access, Rescue, Stability, Ventilation, Bridging, elevated streams, elevated work position |
|
|
Term
|
Definition
| Standard for life safety rope and system components |
|
|
Term
| List 3 examples of Natural material rope |
|
Definition
|
|
Term
| Litst the 4 examples of Synthetic Material |
|
Definition
| Nylon, Polyester, Polypropylen, Polyethylene |
|
|
Term
| List the 4 types of construction methods for rope |
|
Definition
| Laid, Braided, Braid on Braid, Kern Mantle |
|
|
Term
| When should a rope be inspected |
|
Definition
| monthly or after each use |
|
|