Term
| Primary responsibility of the company officer |
|
Definition
| Keep the members under his command as safe as possible |
|
|
Term
| FF's mindset is based on a compilation of factors |
|
Definition
Attitude
preparedness
and an overall belief that a serious event will happen |
|
|
Term
|
Definition
| Stop the elevator two floors below the fire for and walk up |
|
|
Term
|
Definition
| It wasn't until 1977 that factual statistics were first collected in the American Fire Service |
|
|
Term
|
Definition
| Has been described by many as containing solid gasoline as the primary fuel |
|
|
Term
| Single family dowellings of today |
|
Definition
| Are loaded with countless tv's, computer monitors and other various class b combustibles |
|
|
Term
|
Definition
| Increase FF's chances of encountering a deadly flashover if the fire is caught in the growth phase |
|
|
Term
|
Definition
| Can sometimes mask the rapid development of high heat and potential flashover conditions |
|
|
Term
|
Definition
| Is created from a positive attitude and strong self discipline |
|
|
Term
|
Definition
Day dreaming mindset=
complacency and laziness |
|
|
Term
|
Definition
| Equal to a relaxed conversation type mindset |
|
|
Term
|
Definition
| Equal to a preparation mindset |
|
|
Term
|
Definition
Equal to life or death mindset
must be already operating in 3rd gear to transition to 4th |
|
|
Term
|
Definition
| The most important component associated with firefighting mindset |
|
|
Term
| Physical fitness and preparedness |
|
Definition
| Requires a schedule that include a fitness routine at least two to three times a week. Must include cardiovascular fitness as well as muscular endurance |
|
|
Term
| Continual process that never really ends |
|
Definition
| Read study, listen and learn |
|
|
Term
|
Definition
| Keep training positive and productive, and never use as a tool for punishment |
|
|
Term
|
Definition
| Getting prepared, staying prepared, and believing that all your hard work and prep will pay off |
|
|
Term
| The first High rise buildings |
|
Definition
| We're built around the middle of the nineteenth century |
|
|
Term
|
Definition
| In 1853 Elisha Graves Otis invented the first so called safety lift, know today as an elevator |
|
|
Term
| In the 1870's, the use of steel became available to form the framework of a high rise structure. |
|
Definition
|
|
Term
| Definition of a high rise building |
|
Definition
| NFPA 101, life safety code; a building greater than 75 feet in height where the building height is measured from the lowest level of fire department vehicle access to the floor of the highest occupiable story |
|
|
Term
|
Definition
| 9 to 15 ft per floor, generally a building can be classified as a high rise if it is roughly five to eight stories or more in height |
|
|
Term
| strictly from fire service point of view |
|
Definition
| Ultimately any building where all or even just portions of the building are beyond the reach of ground-based firefighting equipment, specifically aerial ladders could and should be considered as a high rise |
|
|
Term
| Average distance of a floor in a residential high rise building |
|
Definition
9 to 10 feet in a residential high rise building
typical commercial high rise with floors 12-15 feet or more per floor |
|
|
Term
|
Definition
|
|
Term
|
Definition
| The vertical, natural air movement throughout a high rise building caused by the difference in temperatures between the inside air, and the outside air |
|
|
Term
| Fire detection and protection system |
|
Definition
| Anytime there are multiple locations of alarm, the lowest level of alarm should be investigated first |
|
|
Term
| fire extension in a high rise can occur in a variety of ways |
|
Definition
- Poke through construction
- curtain wall gap
- auto exposure
|
|
|
Term
| generic term for auto exposure |
|
Definition
|
|
Term
| spandrel distance on the exterior of the building |
|
Definition
| The distance between floors that in most cases affords spme protection from auto exposure |
|
|
Term
| the two most critical factors associated with ops in multistory buildings are: |
|
Definition
|
|
Term
| preconnected 1"3/4 hose over 300ft |
|
Definition
| Rquire excessive engine pressure in order to overcome friction loss |
|
|
Term
| if the fire is on 2nd, 1st, street level, below grade, |
|
Definition
Standpipe system should be bypassed and a line stretched from the apparatus pumper outside
Standpipe system should still be supplied, but first handline should come from the outside |
|
|
Term
| Standpipes in shopping malls |
|
Definition
| Can usually be described as a horizontal standpipe |
|
|
Term
| Ideally stretching from the pumper at fires in buildings with horizontal SPs |
|
Definition
| Should become the primary method-it is the safest |
|
|
Term
|
Definition
Designed specifically for occupant use
Not to be used by ffs. Not designed to deliver the fire flow necessary |
|
|
Term
|
Definition
| Use by both occupants and fire dept. Personnel |
|
|
Term
|
Definition
| Typically found in many parking garages |
|
|
Term
|
Definition
| Where the sprinkler system and the standpipe for manual firefighting are actually supplied by the same standpipe riser |
|
|
Term
| SP and sprinkler are separate, not a combination system |
|
Definition
Decision: FDC for the stand pipe supplied first.
sprinkler and FDC SP must be pumped into. |
|
|
Term
| Standpipe defined in NFPA 14; |
|
Definition
| as an arrangement of piping, valves, hose connections located in such a manner that water can be discharged in streams through attached hose and nozzles, for the purposes of extinguishing a fire, thereby protecting a building or structure and its contents in addition to protecting occupants |
|
|
Term
| Water supply for standpipe system |
|
Definition
- Maybe from city main, gravity tank, pumps, or a combination of those components
|
|
|
Term
|
Definition
| The vertical or horizontal main used to deliver the water to all areas of the building |
|
|
Term
| Fire protection handbook definition of stand pipe systems |
|
Definition
| Fixed piping systems with associated equipment, that transports water from a reliable water supply to designated areas of the building where hoses can be deployed for firefighting |
|
|
Term
|
Definition
For fire dept use
21/2" discharge outlets
required to deliver a rated flow of 500gpm at the topmost, or hydraulically most remote. |
|
|
Term
|
Definition
Occupant use
1 1/2" discharge outlets
may have 1 1/2" single jacketed hose attached
100 gym required from the hydraulically most remote standpipe outlet |
|
|
Term
|
Definition
Combination of class 1 and II systems.
can have both 2 1/2 and 1 1/2" outlets or 2 1/2 with 1 1/2" reducer attached |
|
|
Term
|
Definition
Combined system
class I or III that also supply water to sprinkler system |
|
|
Term
|
Definition
| Piping that is normally filled with pressurized air |
|
|
Term
|
Definition
| Piping that is filled with water at all times |
|
|
Term
|
Definition
| Dry, piping normally filled with air that may or not be ppressurized may have a deluge valve |
|
|
Term
|
Definition
The pipe, fittings, and valves used for the standpipe system are rated for pressures of up to only 300
nfpa14 also recommends that the maximum pressure within the system at any point should not exceed 350 psi |
|
|
Term
| Valves located throughout a typical standpipe system |
|
Definition
- Pivs, os&y, check valves and sectional control valves control the flow of water throughout the stand pipe system
|
|
|
Term
|
Definition
| Hose connections should be unobstructed, and are required to be located not less than 3 feet or more than 5 feet above the floor |
|
|
Term
pressure regulating devices
Pressure reducing valves (prvs) |
|
Definition
In most cities, SPs, especially those in tall high rise buildings, are typically equipped with pressure regulating valves
Can be found in 2 locations: zone floor control valves for combination SP/sprinkler or at SP hose valve outlets |
|
|
Term
|
Definition
- Nfpa14
- Designed for the purpose of reducing, regulating, controlling, or restricting water pressure in order to limit SP outlet pressure
- 3 types: pressure-rwatricting devices, Pressure-reducing valves, Pressure-control valves
|
|
|
Term
|
Definition
| A metal disk with a restricting orifice. If used, should always be installed at hose couplings to allow for easy removal. |
|
|
Term
|
Definition
| Nfpa14 recommendarions, most fire codes require them for outlets of systems where static pressure could exceed 175 psi. Most prvs act as check valves |
|
|
Term
|
Definition
- Valve: internal components assoc. With its pressure regulation that cannot be removed.
- Device: when there are either external componenets such as limiting devices, or internal components such as an orifice plate. Seperate from actual valve and can be removed.
|
|
|
Term
| 4 categories of pressure-regulating and reducing valves |
|
Definition
- Factory preset
- Field adjustable
- Fireground adjustable
- Fireground removable
|
|
|
Term
|
Definition
| Can also be defined simply as the art or science of moving manpower and equipment from point A to B. |
|
|
Term
|
Definition
| The primary tool used to move people to the upper floors of a high rise building |
|
|
Term
|
Definition
| Logistical problem of moving firefighters and equipment to the upper floors of a high rise building. |
|
|
Term
|
Definition
| HR fires are a six sided multidimensional problem |
|
|
Term
|
Definition
- Life safety
- Incident stabilization
- Property conservation
|
|
|
Term
| Lloyd layman's indirect attack |
|
Definition
| That there should be no occupants where the indirect attack takes place |
|
|
Term
|
Definition
| Forcefully drive all the heat, fire, smoke and other products of combustion all the way around the center core and back on top of advancing firefighters |
|
|
Term
| Minimum topmost standpipe outlet psi standards |
|
Definition
| 65 psi in existing buildings, and 100 psi in newer buildings must be prepared to account for friction loss, nozzle and head pressure |
|
|
Term
| Weight of smooth bore/solid stream nozzle |
|
Definition
Weighs less than 1 pound.
Most combination fog nozzles weigh between 5-6 pound range |
|
|
Term
|
Definition
| The pressure of a fluid on a body, when the body is at rest relative to the fluid |
|
|
Term
|
Definition
| After the nozzle is opened gauge pressure will drop |
|
|
Term
|
Definition
Standpipe inline gauge
probably the most important of the water delivery appliances second only to the nozzle |
|
|
Term
|
Definition
| Locate, confine and extinguish the fire |
|
|
Term
| The first function of the engine company at any structural event, including high rise and SP operations is: |
|
Definition
| To establish a sustained water supply |
|
|
Term
|
Definition
| Items such as bldg construction, type of occupancy, size of the bldg including the area and height. What type of auxiliary appliances exist within the bldg, whether the bldg has standpipes |
|
|
Term
|
Definition
| The fire is left unchecked, and with a sufficient supply of O2 will likely grow, in most cases doubling in size every 30 seconds to one minute |
|
|
Term
|
Definition
| Hook up on the floor below |
|
|
Term
|
Definition
| Attack line can be stretched dry to the apartment door |
|
|
Term
|
Definition
| Fire is not confined to the apartment, has control over even a small portion of the public hallway |
|
|
Term
|
Definition
| The key is to cool the upper area of the fire environment |
|
|
Term
| The nozzle team operating a 2 1/2" handline |
|
Definition
| Must consist of at least two firefighters |
|
|
Term
|
Definition
The vertical, natural air movement throughout a high rise building caused by the difference in temperatures between the inside air and the outside air.
strong draft from the ground floor to roof.
the colder the weather and the higher the bldg the greater the stack effect |
|
|
Term
|
Definition
| As the smoke rises inside a tall high rise building, it cools down, loses its buoyancy, stops traveling upward, stratifies and begins to spread laterally |
|
|
Term
| Mushrooming of smoke at the upper levels of a fire building |
|
Definition
| Smoke can quickly bank down and build up. Dangerous smoke conditions on several upper floors |
|
|
Term
|
Definition
| The rule of thumb was to actually shutoff the HVAC System down immediately upon arrival at a fire in a high rise building |
|
|
Term
|
Definition
| Bottom line make every effort to avoid using a fire/smoke tower as an attack stair. |
|
|
Term
|
Definition
| exercise good discipline in spotting the apparatus. |
|
|
Term
| Spotting a pumper at an FDC |
|
Definition
First make every attempt to spot the pumper as close to the FDC or preferably within 50 feet or one length of hose
spotting the pumper so that the FDC is on the opposite of the pumper from the pump panel |
|
|
Term
|
Definition
Most important of the two overhauls
check all six directions
begiat with the fire apt. Then any exposure apts. if fire extended into public hallway, then other apts. must be checked for extension
next, the apt. on the floor above directly above the fire apt. Then the top floor |
|
|
Term
|
Definition
| Systematic and fast as possible |
|
|
Term
|
Definition
Must include all areas, and is completed much slower, more methodical
Goal is to have a fresh search team with an unbiased perspective |
|
|
Term
|
Definition
- Every search operation must be based on fundamentals, including orientation to a wall, and/or a search rope which will lead members to safety
|
|
|
Term
|
Definition
| The main search rope or tether should be anchored to a point well outside of the search area, either outside completely, or to a stairwell handrail inside a commercial high rise building |
|
|
Term
|
Definition
| Referred to as radio to radio channels |
|
|
Term
|
Definition
| Allows for two different types of ops to be under the ops section |
|
|
Term
| Ics organizational sections |
|
Definition
- Operations
- planning
- Logistics
- Finance/administration
|
|
|
Term
|
Definition
| The preferred location is at or below staging and as close as possible, ideally one floor below |
|
|
Term
|
Definition
| An appropriate location for staging is at least two floors below the fire floor, on a floor not contaminated by smoke or heat conditions |
|
|
Term
|
Definition
| The first officer to arrive at the scene of an emergency incident should become the initial incident commander |
|
|
Term
|
Definition
|
|
Term
|
Definition
FFs can utilize to remove an incapacitated FF or civilian.
|
|
|
Term
|
Definition
First RIT at a high rise building or standpipe equipped building should be placed as close as possible to the primary fire attack location
the floor below the fire |
|
|