Term
| A combination of letters and numbers used to designate a specific item without describing it is a...? |
|
Definition
|
|
Term
| A descriptive wording reference concerning a COMSEC subject is a...? |
|
Definition
|
|
Term
| The designation "TSEC/" preceding an item designator signifies...? |
|
Definition
|
|
Term
| Amendments and changes to COMSEC publication are distributed by a...? |
|
Definition
|
|
Term
| For COMSEC items you must enter on AFCOMSEC form 16, COMSEC Account Daily-Shift Inventory the...? |
|
Definition
|
|
Term
| Normally COMSEC users are issued no more than one months supply of material; however, is a user needs more for an effective mission, the COMSEC manager issues sufficient COMSEC aids to meet the need, but no more than...? |
|
Definition
|
|
Term
|
Definition
| The practice of using filters at the first service disconnect. |
|
|
Term
| What is low-level signaling? |
|
Definition
| Equipment that uses low voltage and current levels to reduce compromising emanations. |
|
|
Term
|
Definition
| Equipment that processes classified information before encryption and after decryption. |
|
|
Term
| Is most "commercially available off the shelf" equipment TEMPEST approved? |
|
Definition
| No, most of this equipment is nto designed with TEMPEST protection in mind. |
|
|
Term
| What is the objective of RED/BLACK signal distribution? |
|
Definition
| To provide an organized scheme to transfer signals from the source(transmitter) to the sink (reciever) in such a manner that RED/BLACK integrity is maintained, interferenced is not intercepted from other sources, and interference is not created. |
|
|
Term
| Typically what type of output (line side) signals are generated by modems, and what is the frequency range of these signals? |
|
Definition
| Analog signals in the VF range of 300 to 4000 Hz. |
|
|
Term
| How can the possibility of EMI be minimized when using digital signalling? |
|
Definition
| Using low-level voltage, properly terminating all cable pairs, and ensuring sheilds are properly closed and grounded. |
|
|
Term
| Why are patch panels installed in facilities having a RED and BLACK distribution sytem? |
|
Definition
| Allows equipment and signal paths to be interchanged in the event of a failure. |
|
|
Term
| Where are surge, transient, EMI/RFI, and EMP/HEMP protective measures applied to signal lines entering and leaving the facility? |
|
Definition
| At the facilty entry plates. |
|
|
Term
| Why are signal distribution schemes used in RED and BLACK enviroments? |
|
Definition
| To ensure the proper segregation and integrity of signals. |
|
|
Term
| When is filtering of signals not nessecary in RED and BLACK enviroments? |
|
Definition
| When TEMPEST approved euipment is being used, the lines are encrypted, proper RED/BLACK separation is maintained, and proper installation procedures have been used. |
|
|
Term
| In regard to emission security, what is the basic purpose of filter, isolators, and shields? |
|
Definition
| Attenuation of undesirable signals that attempt to pass through these devices. |
|
|
Term
| How does filtering help reduce compromising emanations? |
|
Definition
| By shunting the interfering or compromising energy to a return path and reflecting it back to the source. |
|
|
Term
| Why should an external barrier of a facilty use filters (Preceded by surge arrestors) in preference to isolators? |
|
Definition
| To prevent arcing when a large incoming voltage transient encounters an open circuit. |
|
|
Term
| What is ground in relation to signals? |
|
Definition
| Ground is merely an agreed upon potential to which signal voltages may be referenced. |
|
|
Term
| What type fo field does ferrous and nonferrous shielding material attenuate? |
|
Definition
| Ferrous are used for magnetic fields, whereas nonferrous materials are used for electrostatic fields. |
|
|
Term
| When you use non-TEMPEST equipment and/or high-level signalling, what configuration of the RED and BLACK power distribution may be required? |
|
Definition
| Seperated RED and BLACK power distribution. |
|
|
Term
| If possible, where should prime power source be located when emmission security is a concern? |
|
Definition
| Totally Contained within the CS. |
|
|
Term
| What two types of powers systems are used in facilties? |
|
Definition
| Technical and non-technical |
|
|
Term
| What is the purpose of a non-technical power system? |
|
Definition
| To provide power to air-conditioning, lighting, and houskeeping functions. |
|
|
Term
| What is the purpose of a technical power system? |
|
Definition
| Provide power to the equipment associated with the mission. This includes any lighting and enviromental equipment essential to system operation. |
|
|
Term
| Why should power line filters be custom designed for individual equipment? |
|
Definition
| This allows the filter to be designed specifically to the parameters and characteristics of the equipment. |
|
|
Term
| When is it permissable to filter the power of a BLACK prcessor? |
|
Definition
| When the entire facility has been provided with filtered power. |
|
|
Term
| Why should you install disconnect devices, noninductive ringers, and speech supression devices on a telephone that serves an LEA? |
|
Definition
| To prevent the telephone from becoming a microphone and compromising the the LEA |
|
|
Term
| Why is line separation immportant in minimizing emanations? |
|
Definition
| The electromagnetic field surrounding a conductor reduces with distance |
|
|
Term
| Whom should you consult BEFORE moving or installing any classified processor or moving or installing other devices near classified processors? |
|
Definition
| Cognizant TEMPEST authority |
|
|
Term
| Which areas are not included in a technical evaluation? |
|
Definition
| Job proficiency and knowledge of the maitenance technician. |
|
|
Term
| The evaluation that gives the commander a factual, objective assesment of a section's ability to meet its mission is a...? |
|
Definition
|
|
Term
| What two discrepancy catagories are documented on a technical evaluation report? |
|
Definition
|
|
Term
| A major discrepancy is any dificiency that...? |
|
Definition
| creates an unsafe condition or may cause a security violation. |
|
|
Term
| What are the organization's responsibilities in the communication and information system process? |
|
Definition
| Identifies communications and information systems requirements and allocates resources. |
|
|
Term
| Who approves the technical solution? |
|
Definition
|
|
Term
| Commercial equipment manuals are...? |
|
Definition
| provided by the vendor and are similar to TOs. |
|
|
Term
| What detailed information is found in a TO? |
|
Definition
| Illustrated parts breakdown, theory of operation, and equipment operational limitations. |
|
|
Term
| Who is responsible for the routine application of risk management |
|
Definition
|
|
Term
| The fundamental goal of risk management is to enhance mission effectivenessat all levels while preseves assets and safeguarding...? |
|
Definition
|
|
Term
| What does Operational Risk Management (ORM) provide that determines which risk or what level or risk is unnessecary? |
|
Definition
|
|
Term
| What is step one of the six step ORM process? |
|
Definition
|
|
Term
| When an interlock switch is disconnected what precaution should be taken? |
|
Definition
| Place an appropriate sign on the equipment. |
|
|
Term
| A grounding stick is used for what other tasks besides discharging capacitors? |
|
Definition
| Checking for stray high voltage |
|
|
Term
| What type of tool should be used when working on energized communications electronics (C-E) equipment? |
|
Definition
|
|
Term
| What can be used on tools to help protect them? |
|
Definition
|
|
Term
| Mallets with plastic heads are used for...? |
|
Definition
| Jobs where a steel hammer would mar the work. |
|
|
Term
| General purpose drill bits have...? |
|
Definition
|
|
Term
| Long nose pliers are not to be used for...? |
|
Definition
| Tightening nuts and bending large guage wires or sheet metal. |
|
|
Term
| Human factors that contribute to hazardous situations fall into what two major catagories? |
|
Definition
|
|
Term
| The wearing of gloves, face shield, and apron are nessecary when handling cathode-ray tube (CRT) mainly to protect against...? |
|
Definition
|
|
Term
| How should you treat a low voltage circuit with a current of 50 milliamperes? |
|
Definition
| As a high voltage circuit |
|
|